Line 13: Line 13:


=== Powering ===
=== Powering ===
LaserDistanceLCD uses 220VAC for powering. The power connector is on the back side in the bottom left corner, marked on the PCB with '''"220V".''' Next to the powering terminal screw, is the switching port, marked on the PCB with '''"P-SW1"'''. It interrupts the powering of the device. If You need this function, just install an interrupter for 220VAC.
LaserDistanceLCD uses 220VAC for powering. The power connector is on the back side in the bottom left corner, marked on the PCB with '''"220V".''' Next to the powering terminal screw, is the switching port, marked on the PCB with '''"P-SW1"'''. It interrupts the powering of the device. If You need this function, just install an interrupter for 220VAC. By the wiring, use minimal 1.5mm2 cable

Revision as of 10:41, 26 November 2022

Overview

LaserDistanceLCD
LaserDistanceLCD

LaserDistanceLCD is a panel-mounted measuring device. It uses laser light to measure the distance between the sensor and the object. The measurement is based on the ToF (time of flight) of light from the source (sensor) and is the reflection (object).

The measured distances can be shown in millimeters (mm) or inches (inch) in 18 different languages. Configuration of a device is made with LaserDistance software.

Hardware installation

The LaserDistanceLCD has to be mounted on a panel. The hole diameters have to be 97 x 72mm. The backside of the device is 45mm deep, so leave enough place to connect the cables. Powering off the device can be done with 220VAC or 110VAC. The sensor is connected with a 1-meter-long flat cable to the device.

By the installation place, please note that a device is about 45mm bold, so You have to leave enough place to access the cables and connectors from the sensor and from the programmer.

The sensor has two mounting holes, 20mm distance. By the mounting of the sensor, note that it needs to have a clear view of the measured object. Don't install the device in a humid environment, water tanks, etc. Also, the device must be used indoors and is not made for outdoor usage. Presents of high dust can affect the measurement. The possibility to reflect laser light can affect the measuring range.

Powering

LaserDistanceLCD uses 220VAC for powering. The power connector is on the back side in the bottom left corner, marked on the PCB with "220V". Next to the powering terminal screw, is the switching port, marked on the PCB with "P-SW1". It interrupts the powering of the device. If You need this function, just install an interrupter for 220VAC. By the wiring, use minimal 1.5mm2 cable