LaserDistance: Difference between revisions
No edit summary |
No edit summary |
||
Line 50: | Line 50: | ||
In the lower part of the window can You see the Device ports and the photo of the device ports. Depending of the device, it can chow You the power connection, the switching port, connectors for sensor, relays etc. On the right bottom side is the photo of the connecting side and the position of the ports, so You can easily find the ports. |
In the lower part of the window can You see the Device ports and the photo of the device ports. Depending of the device, it can chow You the power connection, the switching port, connectors for sensor, relays etc. On the right bottom side is the photo of the connecting side and the position of the ports, so You can easily find the ports. |
||
== Measurement == |
|||
Measurements can be programmed in right top corner. Before You can begin with measurement, You must choose how long will be measured. This can be defined with the Measurement time (minutes), minimal time is 1 minute. After You defined the duration, You must choose the file name, where will be stored the measured data. It will have .csv extension. |
|||
The file is a textual file, can be edited with Notepad or any other text editor. The measured values are presented in format: |
|||
<code>time , distance</code> |
|||
An example of measurement: |
|||
<code>15 , 56</code> |
|||
That means that in 15. second of the measurement was measured 56mm distance. With this values, You can generate graphics or other scientific data analyzes. |
Revision as of 18:02, 4 November 2022
Description
LaserDistance is a software designed to use with LaserDistanceDIN, LaserDistanceUSB, LaserDistanceControl, and LaserDistaceLCD devices. It can configure a device language and measurement unit system on all devices. LaserDistanceDIN and LaserDistanceControl can be configured with the alarming behavior (visual and audio signals) and the relays. The current status of the configuration is also presented if the device is connected.
The configurations can be downloaded from the device and stored in local files for later examination or backup purposes.
The LaserDistance software can make measuring. The data are stored as Comma Separated Values (SCV) and contain the measured time (seconds from the beginning of the measurement) and the measured value (in mm or inch).
Supported devices
With a LaserDistance software You can use four devices:
- LaserDistanceDIN
- LaserDistanceControl
- LaserDistaceLCD
- LaserDistanceUSB
Installation and setup
You can download the program from the software repository. The LaserDistance is a freeware software, can be installed on Windows 10 and 11. After the installation, You can start it from the Start Menu. At the left right corner is the Connection par of the program. With a scan button You can search for connected devices. Program language can be set from the same part. It supports 18 languages: English, German, French, Italian, Portuguese, Spanish, Dutch, Hungarian, Croatian, Slovenian, Serbian, Czech, Slovak, Polish, Danish, Swedish, Norwegian and Finnish. After You have choose the correct language, restart the program to take effect.
Configuration
Loading the configuration can be done from a connected device or from file. An example of configuration files can be downloaded here. By connecting to the device, the current configuration of the device will be automatic loaded. If the device supports actions, like relays of alarms, it can be set up by Device configuration.
The actions can be set to: Off, above and below the value of the sensor. Triggering value is defined under the action part for the same control.
Example of configuration for Relay 1 - Action Below, value 100mm
In this case, if the distance is under 100mm, Relay 1 will be triggered. This setup can be done to activate some control, if the object is close to sensor.
Example of configuration for Relay 2 - Action Above, value 200mm
In this case, if the distance is over 200mm, Relay 2 will be triggered. This setup is used to activate some control if the object move away from the sensor.
Device language can be changed by drop down menu, it support the same 18 languages as the program: English, German, French, Italian, Portuguese, Spanish, Dutch, Hungarian, Croatian, Slovenian, Serbian, Czech, Slovak, Polish, Danish, Swedish, Norwegian and Finnish After You changed the language, You must save the configuration to the device. Measurement units can be configured as metric or imperial. By metric, the distance will be measured and presented in millimeters (mm), by imperial in inches (inch). Please note that by configuration in metric mode, use mm as whole numbers, and by imperial use decimals.
Saving the configuration
After You made the configuration, You can save the setup to the connected device, or to file. Saving to device will take immediate change of the configuration, is not needed to restart the device after the new configuration is uploaded. By saving the setup to file, You can always load it into new device or to examine later. Saved configuration are stored as .cfg files. Use whole number for metric units (like 65mm or 149mm) or decimals by imperial units (like 0.635 inch or 16,574 inch). If You made an incorrect setup, the program will warn You about it and will not write the miss-configured parameters into device or to file.
Device information and status
If the device is connected, in left bottom corner is presented the Device information.
- Program version
- Device - name of the connected device
- Sensor - the type of the sensor
- Hardware version - the version of the PCB and the case
- Firmware version - main software of the device
- Distance - measured in mm or inch, updated any one second
On the top middle of the window can You see the Status
It shows the current language and the status of alarms and relays. This statuses are updated ones a second.
In the lower part of the window can You see the Device ports and the photo of the device ports. Depending of the device, it can chow You the power connection, the switching port, connectors for sensor, relays etc. On the right bottom side is the photo of the connecting side and the position of the ports, so You can easily find the ports.
Measurement
Measurements can be programmed in right top corner. Before You can begin with measurement, You must choose how long will be measured. This can be defined with the Measurement time (minutes), minimal time is 1 minute. After You defined the duration, You must choose the file name, where will be stored the measured data. It will have .csv extension.
The file is a textual file, can be edited with Notepad or any other text editor. The measured values are presented in format:
time , distance
An example of measurement:
15 , 56