UVVisIR

From RAPMAS
Jump to navigation Jump to search

Description

UVVisIR is a software designed to use with UVVisIRDIN, UVVisIRUSB, UVVisIRControl, and UVVisIRLCD devices. It is used to configure device language, alarming (visual and audio signals), relay regulation and to perform measurements. On the main window is presented the current sensing values for UV, Vis and IR spectrums and the device current configuration.

For backup purpouse, You can save the configuration to a cfg file, and load it into other device, or to change the stored configuration without connected device.

The UVVisIR software can also make a measurement. You can configure where to store the CSV (Comma Separated Values) file, with the measured value, and the measurement duration, in seconds.

Supported devices

With UVVisIR software You can use four devices:

  • UVVisIRDIN
  • UVVisIRControl
  • UVVisIRLCD
  • UVVisIRUSB

Installation and setup

You can download the program from the software repository. UVVisIR is a freeware software, that can be installed on Windows 10 and 11. After the installation, You can start it from the Start Menu. At the left-right corner is the Connection part of the program. With a scan button, You can search for connected devices. Program language can be set from the same part. It supports 18 languages: English, German, French, Italian, Portuguese, Spanish, Dutch, Hungarian, Croatian, Slovenian, Serbian, Czech, Slovak, Polish, Danish, Swedish, Norwegian, and Finnish. After You have chosen the correct language, restart the program to take effect.

Configuration

Loading the configuration can be done from a connected device or the file. An example of configuration files can be downloaded here. By connecting to the device, the current configuration of the device will be automatically loaded. If the device supports actions, like relays of alarms, or languages, it can be set up by Device configuration.

The actions can be set to Off, Above, and Below the value of the sensor. Triggering value is defined under the action part for the same control.

Example of a configuration for Relay 1 - Action Below, value 300, Sensor Vis.

In this case, the Relay 1 will be activated if the lightning intesinty of Visible light (Vis) is under 300 value, for example, to turn on the floor lighting in garden at evening.

Example of a configuration for Relay 2 - Action Above, value 4, Sensor UV.

In this case, the Relay 2 will be activated if is the Ultra Violet Index higher that 4. Can be used to warn peoples on beach to use sun protection creams, or to find shadow for kids.

Example of a configuration for Relay 3 - Action Above, value 4, Sensor UV.