HydroLevelControl: Difference between revisions
Line 52: | Line 52: | ||
== Software == |
== Software == |
||
HydroLevelControl software is a program designed to read measured data and configure the hardware. It communicates with a USB to Serial TTL, where the TTL is on the hardware side. The software can be downloaded from this page for free. |
HydroLevelControl software is a program designed to read measured data and configure the hardware. It communicates with a USB to Serial TTL, where the TTL is on the hardware side. The software can be downloaded from this page for free. It supports 16 languages: English, German, French, Spanish, Dutch, Hungarian, Croatian, Slovenian, Serbian (Latin), Czech, Slovakian, Polish, Danish, Swedish, Norwegian and Finnish. |
||
{| class="wikitable" align="right" |
{| class="wikitable" align="right" |
||
|+ |
|+ |
||
![[File:HydroLevelControl-Software.png|none|thumb|300x300px|Main screen of HidroLevelControl]] |
! colspan="2" |[[File:HydroLevelControl-Software.png|none|thumb|300x300px|Main screen of HidroLevelControl]] |
||
|- |
|- |
||
|Developer |
|||
⚫ | |||
|RAPMAS |
|||
|- |
|- |
||
|Written in |
|||
⚫ | |||
|C# |
|||
|- |
|- |
||
|Operating system |
|||
⚫ | |||
|Windows |
|||
⚫ | |||
|Size |
|||
|Under 1MB |
|||
⚫ | |||
|Licence |
|||
|Proprietary software |
|||
⚫ | |||
|Website |
|||
|<small>www.rapmas.com/HydroLevelControl/</small> |
|||
|} |
|} |
||
=== Installation === |
|||
The installer can be downloaded online. After start the install process, You will be asked to choose the language of the installation. Please note that a choose language will be the default language at a first start of the program. It can be changed later at any time. The software and the hard |
Revision as of 18:34, 24 October 2021
Description
HydroLevelControl is a bundle of hardware and software designed to measure, present and control the level of fluids. Measurement is based on the hydrostatic pressure provided by the fluid above the pressure sensor. The measured pressure value is converted to a requested data format, according to inserted data, like fluid density, reservoir surface, etc. The measured value can be used to activate the visual alarm (blinking LCD display), sound alarm, and two relays. All this can be configured independently.
Take care that this device can be used only on atmospheric pressure. Installation in an over or under pressured environment can permanently damage the sensor and the device!
Background
The device has a pressure sensor, actually a pressure transducer, that is powered with 5 VDC. Depending on the pressure, it produces a different voltage on output that is measured and converted to pressure. Based on the fluid density, is possible to calculate the height of the fluid above the sensor. With the known height and the reservoir surface, can be calculated the volume and the mass of the fluid.
Specification
Parameter | Value |
---|---|
Hardware | |
Power | 220 VAC or 5 VDC over USB |
Sensor type | Pressure transducer, 5 VDC |
Sensor range | 5 - 15 psi |
Sensor offset | 0.5 VDC (at 0 pressure) to 4.5 VDC (at maximal pressure) |
Inlet size | 1/8”-27 NPT |
LCD | 2.9" with blue background light |
Relay | 2 independent relays, maximal load 2A at 220VAC |
Software | |
Operation system | Windows 8 and Windows 10 |
Communication | Serial over USB, TTL on device |
Software functions | Configuration and measurement |
Hardware
The hardware information.
Software
HydroLevelControl software is a program designed to read measured data and configure the hardware. It communicates with a USB to Serial TTL, where the TTL is on the hardware side. The software can be downloaded from this page for free. It supports 16 languages: English, German, French, Spanish, Dutch, Hungarian, Croatian, Slovenian, Serbian (Latin), Czech, Slovakian, Polish, Danish, Swedish, Norwegian and Finnish.
Developer | RAPMAS |
Written in | C# |
Operating system | Windows |
Size | Under 1MB |
Licence | Proprietary software |
Website | www.rapmas.com/HydroLevelControl/ |
Installation
The installer can be downloaded online. After start the install process, You will be asked to choose the language of the installation. Please note that a choose language will be the default language at a first start of the program. It can be changed later at any time. The software and the hard